Brief Explanation :

The use of different voltages in the circuit of a stage truss chain hoist controller is mainly based on safety, equipment compatibility, and specific application requirements. A 36V safety voltage can

Category : Controller

Get a Quote

Product Details

Product Name: Stage Electric Hoist Controller 

Product Type: Controller 


Stage electric hoist  controller details


The voltage of a stage truss chain hoist controller usually depends on the electric hoist it controls and the application scenario. The use of different voltages in the circuit of a stage truss chain hoist controller is mainly based on safety, equipment compatibility, and specific application requirements. A 36V safety voltage can effectively reduce the risk of electric shock for operators and is suitable for most stage environments with high - safety requirements. A 42V low - voltage control is more common in some equipment that focuses on energy conservation and electrical isolation. It can reduce electromagnetic interference and energy loss while ensuring control functions. A 110V control circuit is often used in stage - specific electric hoists that require long - distance signal transmission or have high requirements for control accuracy. Impact of voltage fluctuations:

Fluctuations in the rated power supply voltage can have a significant impact on the stage truss chain hoist controller and the electric hoist. When the voltage is 10% higher than the rated voltage, the motor of the electric hoist may run overloaded, causing the motor to heat up more, shortening the motor's service life, and may even lead to the motor burning out. When the voltage is 10% lower than the rated voltage, the output power of the motor will decrease, and it may not be able to provide sufficient lifting force, causing the electric hoist to run at a slower speed and affecting the normal progress of the performance. In addition, too low a voltage may also cause the controller to work unstably, resulting in malfunctions or loss of control signals.


If you need further consultation on  Stage Hoist Controller details, please contact Google email

Gmail : info@kemeihoist.com

           zyj@kemeihoist.com

WhatsApp:+86 13920508123




Previous: Intelligent Stage Motor Controller

Next : none

RELATED PRODUCTS .

RELATED NEWS .

Copyright © 2023 Tianjin Kemei Machinery Manufacturing Co., Ltd